This product is available in our stores
- Download007950025880 - (Material Safety Data Sheet) - Cylinder With Hydrogen 1L - (EN)
- Download007950025880 - (Material Safety Data Sheet) - Cylinder With Hydrogen 1L - (CS)
- Download007950025880 - (Manual) - Mobile Set For Hydrogen Tests - 11.02.2019 - (BG)
- Download007950025880 - (Manual) - Mobile Set For Hydrogen Tests - 11.02.2019 - (EN)
- Download007950025880 - (Manual) - Mobile Set For Hydrogen Tests - 11.02.2019 - (HR)
- Download007950025880 - (Manual) - Mobile Set For Hydrogen Tests - 11.02.2019 - (HU)
- Download007950025880 - (Manual) - Mobile Set For Hydrogen Tests - 11.02.2019 - (RO)
- Download007950025880 - (Manual) - Mobile Set For Hydrogen Tests - 11.02.2019 - (RU)
- Download007950025880 - (Manual) - Mobile Set For Hydrogen Tests - 11.02.2019 - (SK)
- Download007950025880 - (Manual) - Mobile Set For Hydrogen Tests - 11.02.2019 - (CS)
Kit for comprehensive leakage testing in car A/C systems – using the R134 and 1234yf refrigerants. The kit consists of an electronic leakage detector, pressure gauges and conduits, all placed in a neat and durable case. The cylinder contains a mixture of 5% hydrogen and 95% nitrogen. The particles are smaller compared to pure nitrogen. This enables operators to find smaller leakages and use a detector for the operation, which is not possible with pure nitrogen.
THE KIT INCLUDES:
• Polypropylene case
• Pressure regulator for cylinders with a capacity of 1-100 l max. 30 bar
• Three-way pressure gauge with hose, valve and scale
• Yellow hose 1000 mm
• Hydrogen cylinder (mixture of nitrogen and hydrogen) - 1 litre
• Reduction for 1-litre cylinders
• Hydrogen leakage detector
• Spare protective cap
• HP quick release fitting for R134a
• HP quick release fitting for R1234yf
The Refrigerant Leak Detector (H2) detector detects hydrogen leakage quickly. Its sensitivity is 5 ppm. A new gas mixture of 5% hydrogen (H2) + 95% nitrogen (N) is used as a cooling agent and in air conditioning systems. For this reason, a good leak detector can help with maintenance and leakage detection, thereby increasing the efficiency of the refrigerant.
• Microprocessor control with advanced digital signal processing.
• Multicolor display.
• High-sensitivity, low-leakage detection selector switch.
• Low battery indicator.
• Semiconductor gas sensor.
• Detection of 5% hydrogen (H2) + 95% nitrogen (N).
• Carrying case included.
• 15.5 "(40 cm) flexible stainless steel probe.
• A reference leak source is included.
• Resetting the surrounding concentration.
• High-Duty DC brushless fan. Automatic zero compensation and background compensation.
Detected gases:
Mix 5% water (H2) + 95% nitrogen (N).
Sensitivity:
Below 5 ppm.
H | M | L | |
95% N2 | 5% H2 2g / year | 15g / year | 30g / year |
How to alarm:
Buzzer, tri-color bar indicator with LEDs.
Power supply:
4 AA size alkaline batteries (6V DC)
Length of pipeline:
40cm (15.5 ")
Dimensions / weight:
173 x 66 x 56 mm (about 400g
Accessories:
Alkaline batteries (AA) X 4 pcs. User manual, transport case.
Battery life:
Approximately 7 hours of normal use.
Automatic power off:
10 minutes
Turn off automatic power off:
Press and hold the "Hi" button, then turn on the meter.
Warm-up time:
About 45 seconds
Temperature and humidity:
0 ~ 40 ° C, <80% moisture content. or.
Temperature and humidity of storage:
-10 ~ 60 ° C, <70% moisture. or.
Height n.p .:
<2000 m (6500 ')