Modern systems of direct gasoline injection (G-DI, FSI, HPI, JTS), for proper testing of injectors used in these systems, require devices with high operating pressure. Magneti Marelli offers devices for testing and cleaning such injectors.
Device characteristics:
• Test all types of electromagnetic and piezo injectors (0-300 V / 0-35A)
• Operation of 1 or 4 injectors (GDU4R)
• Working pressure up to 300 or 550 bar
• Electronic measuring system
• Dynamic mass measurement for the GDU*R series (accuracy: 0.2%, repeatability: 0.05%)
• Static mass measurement for GD1R series (Resolution: 0.1mm3, accuracy: 0.6%)
• Protect the control board from damage
• Unique PIEZO stack regeneration function
• Internal cleaning of injectors - MACC (versions * / F)
• Free database update
• Operation in automatic mode (only in GD1R-E / 30 manual pressure regulator)
• Test time: 5-15 mins (GDU2R / GDU4R) and 7-8 mins (GD1R)
• Built-in 10 “(8” GD1R) tablet with Android
• Clearly presented test results with the possibility of printing
• Available adapter for power supply all types of injectors
Performed tests:
R2LC
Electrical test: kΩ/μF; Ω/mH
CFL
Check For Leaks test (injector internal or external)
NLT
Nozzle Leakage Test @High Pressure
iVM (FL, PL, EM, LL, PI)
Injector Volume Measuring test (full-load, part-load, emissions, low-load, pre/post-injection tests and more…)
RSP
Injector nozzle Response-time test.
SPR
Dynamic Spray test performed in all testing conditions.
MM Code | Model | Max operating pressure |
Internal injector cleaning |
Measuring system |
Number of testing slots |
007935101500 | GD1R-E/30 | 300 bar | NO | Static mass measurement | 1 |
007935101510 | GD1R-D/30 | 300 bar | NO | Static mass measurement | 1 |
007935101600 | GDU.2R/30 | 300 bar | NO | Dynamic mass measurement | 1 |
007935101610 | GDU.2R/30/F | 300 bar | YES | Dynamic mass measurement | 1 |
007935101620 | GDU.2R/55 | 550 bar | NO | Dynamic mass measurement | 1 |
007935101630 | GDU.2R/55/F | 550 bar | YES | Dynamic mass measurement | 1 |
007935101160 | GDU.4R/30 | 300 bar | NO | Dynamic mass measurement | 4 |
007935101590 | GDU.4R/30/F | 300 bar | YES | Dynamic mass measurement | 4 |
007935101170 | GDU.4R/55 | 550 bar | NO | Dynamic mass measurement | 4 |